Determination of Formation Constants by a Step Drawdown Test at the “University City” Site in Banja Luka
Keywords:
Unconfined aquifer, Delayed yield, Step drawdown test, Simplified numerical methodAbstract
This paper presents hydrogeological characterization of the alluvial aquifer at the "University City" site on the left bank of the Vrbas River in Banja Luka, Bosnia and Hercegovina. A step drawdown test with three successively increasing pumping rates (1.0, 1.8, and 2.5 l/s) was carried out at well B3, with groundwater-level drawdown and recovery monitored at well B3 and piezometer P1 over 34.7 hours using automatic dataloggers. The time-drawdown curve at P1 exhibits the characteristic "S" shape form of an unconfined aquifer with delayed gravity yield: an early steep segment reflecting confined-type storage release, an intermediate flattening caused by slow gravity drainage, and a late steep segment approaching the Theis curve. Aquifer type was identified from the shape of the curve, and preliminary formation constants were obtained by Neuman type-curve matching of the time-drawdown data for the first pumping rate. Final parameter values were refined by fitting observed drawdowns and recovery at all three pumping rates simultaneously, with calculated drawdowns from the numerical model based on principle of superposition („Inverse procedure“). The resulting formation constants are: transmissivity T = 7.08–7.20 × 10⁻³ m²/s; specific yield Sy = 0.125–0.140; elastic storage coefficient S = 0.013–0.020; specific storage SS= 2.54–3.91 × 10⁻³ 1/m; horizontal hydraulic conductivity KH = 1.39–1.41 × 10⁻³ m/s; vertical hydraulic conductivity Kv = 2.58–2.62 × 10⁻⁴ m/s; and anisotropy ratio kD ≈ 0.186. Well-loss coefficients for B3 are A₁ = 2.6 (linear) and B = 9500 (quadratic). The number of the corresponding type curve is β = r/B = 0.4, delayed-yield index is 1/α ≈ 600 s, and the influence of delayed yield on drawdown ceases after approximately 30 minutes of pumping. The results provide the first baseline formation constants for this stretch of the Vrbas alluvium and demonstrate that a step drawdown test, interpreted with type curves method and method of inverse procedure, can yield consistent unconfined-aquifer parameters from one pumping well and a single observation piezometer.
Downloads
References
Boulton, N.S. (1963). Analysis of data from non-equilibrium pumping tests allowing for delayed yield from storage. Proceeding of the Institution of civil Engineers, vol. 26, No. 6693.
Gambolati, G. (1976). Transient free surface flow to a well: An analysis of theoretical solutions. Water Resources Research, Vol. 12, pp. 27-39.
Hantush, M.S. & Jacob, C.E. (1955). Non-steady radial flow in an infinite leaky aquifer. Transactions American Geophysical Union , Vol. 36, No. 1.
Kruseman, G.P. & de Ridder, N.A. (1994). Analysis and Evaluation of Pumping Test Data. Sec.Ed., International Institute for Land Reclamation and Improvement, Wageningen, The Netherlands.
Mojičević, M. et. al. (1969). Karta i tumač OGK SFRJ - List Banja Luka. Institut za geološka istraživanja Sarajevo, BiH.
Neuman, S.P. (1975). Analysis of Pumping Test Data From Anisotropic Unconfined aquifers Considering Delayed Gravity Response, Water Resources Research, Vol. 11, No. 2, pp.329-342.
Prickett, T.A. (1965). Type-curve solution to aquifer tests under water-table conditions. Ground Water, 3 (3), 5.
Rorabaugh, M. J. (1953). Graphical and Theoretical Analysis of Step Drawdown Test of Artesian Well. Proceedings of the American Society of Civil Engineers, Vol. 79, No. 362, pp. 1-23.
Streltsova, T.D. (1972). Unconfined aquifer and slow drainage. Journal of Hydrology, Vol. 16, pp. 117-124.
Walton, W.C. (1960). Application and limitation of methods used to analyze pumping test data. Water Well Journal, Feb.-March.